UV cabinet/PCR workstation, double, dual UV protection lamp and UV recirculator, 3 int. power sockets
UV cabinet/PCR workstation, double, dual UV protection lamp and UV recirculator, 3 int. power sockets

UV cabinet/PCR workstation, double, dual UV protection lamp and UV recirculator, 3 int. power sockets

SKU: MB2005
£5,200.40
{price} OFF

10+ In Stock

  • Guarantee Safe
    Checkout

Secure_Checkout_Options_-_Appleton_Woods

Description

UV cabinet/PCR workstation

The Grant UV cabinet/PCR workstation is a large-capacity stainless steel PCR UV cabinet workstation with additional space for equipment and accessories to allow for more comfortable and convenient working in PCR applications.

These UVT-S-AR cabinets are equipped with an open UV lamp installed in the upper part of the hood. UV radiation from these lamps effectively disinfects the working area chamber, inactivating DNA / RNA fragments during 15-30 minutes of exposure. The digital timer controls the duration of direct UV irradiation. An additional daylight lamp provides a bright, clear working area.

They are equipped with a high-efficiency flow-type bactericidal UV cleaner-recirculator which provides constant decontamination inside the cabinet during operation. The UV cleaner-recirculator consists of a UV lamp, dust filters, and a fan. The recirculation effect increases the maximum density of the UV light making it sufficiently effective for DNA / RNA inactivation. The recirculator processes 360 UV-cabinet volumes per hour, creating permanently aseptic conditions within the cabinet.

UV cabinet/PCR workstation features:

  • Built-in UV cleaner-recirculator both increases the maximum density of UV light and generates 25 m³/h airflow exchange €“ prevents unwanted contamination and protects the user from direct UV light during manipulation
  • White lamp provides local illumination of the workplace to optimize visual control during operations
  • Automatic switch-off of irradiated UV light when the door is opened
  • Convenient, easy-to-use digital timer for accurate control of UV exposure
  • UV-protective film on glass panels
  • UV exposure controlled by 24h digital timer
  • UV surface irradiation €“ via dual 30W 254nm open UV lamp
  • Front opening with three adjustable positions for ease of access
  • Internal Power Socket

[vc_row gap="" style="classic" shape="rounded" color="grey" no_fill="" spacing="" c_align="left" autoplay="none" collapsible_all="true" c_icon="plus" c_position="left" active_section="2" title=""][vc_column][vc_tta_accordion active_section="2" collapsible_all="true"][vc_tta_section title="Technical Specifications" tab_id="1568287546718-f87746b5-a214"][vc_column_text]

UVT-S-AR SKT
Dimensions (HxWxD) 585 x 585 x 1245mm
Weight 58kg
Construction stainless steel frame and working area
Panels Glass with UV-protective film
Open UV lamp, 30 W bactericidal, ozone free 2
UV recirculator, 30W (efficiency >99% per 1 cycle) 1
White lamp for workplace illumination 30W 1
Internal power outlets 3
Internal working area 1200mm x 520mm
Flow rate m3/h 7

[/vc_column_text][/vc_tta_section][/vc_tta_accordion][vc_column_text]

Need more info? Contact Lana Jackson, our Equipment Sales Manager 

Request More Info

Delivery

Return Policies

Request Specific Product Information

If the product info you require is not listed above, our dedicated UK team of lab product experts will be happy to provide what you are looking for. 

Delivery

Standard Delivery £15.00 +VAT. 

Delivery Schedule All in stock items will be dispatched within 2 working days.

Exemption The standard delivery fee does not apply to certain items. These may be subject to additional shipping charges, for example capital equipment items or dry ice shipments. Please contact our office for details.

Back Orders If your item is not in stock, we will back order it for you. Any in stock items on your order will be part-shipped on our standard delivery schedule at no additional charge. You will always be emailed with the option to cancel your order if you would rather not wait.

Return Policies

All goods supplied by the Company shall be examined and checked immediately upon receipt by the buyer. 

The company should be notified in writing within 48 hours of any damages, shortages or errors in the consignment. No claim whatsoever will be accepted by the Company in respect of any damage or shortage after this time. Where there is a total loss of the Goods in transit, the customer must notify the company within seven days of the invoice. If no such notice is given, the Goods shall be deemed to have been supplied in accordance with the order and to have been accepted by the Buyer. Goods that conform to the Buyer’s order may not be returned without the consent of the Seller. 

The Seller reserves the right to impose a handling charge of 20% of the net invoice value for returned Goods. The Seller reserves the right to refuse to accept any Goods returned, for whatever reason, if after inspection such Goods or their packaging prove unsatisfactory in any way. The Buyer is responsible for ensuring that any returns are free from biological and chemical hazard. The seller reserves the right to refuse to accept Goods which in its view present a hazard to its staff or which may infringe the Health & Safety at Work legislation.

Related Products

Account Holder Benefits

Rewarding You and Your Lab For Shopping Local

As a UK independent lab supplier, we really appreciate you shopping local with us and supporting the UK science economy. To say thanks, all Appleton Woods account holders receive: 
  • Improved credit terms
  • Exclusive product offers and deals
  • Free entry into our monthly prize draws
  • Tickets to upcoming events
Screenshot_2024-09-05_at_13
AdobeStock_874167913_Preview
pexels-caleboquendo-7697342
Screenshot_2024-07-31_at_15