Width
  • 3ft/0.9m
  • 4ft/1.2m
  • 5ft/1.5m
  • 6ft/1.8m
HEPA
  • Single
  • Double
  • Guarantee Safe
    Checkout

Secure_Checkout_Options_-_Appleton_Woods

Description

Faster SafeFAST Classic vertical laminar flow cabinets are Class II Microbiological Safety Cabinets - designed and built to performance requirements of the EN-12469:2000 European Standard and NSF/ANSI 49 American Standard, with 70% of the air re-circulated via the main H14 HEPA/ULPA filter according to EN 1822 within the cabinet, whilst the remaining 30% is discharged through an exhaust H14 HEPA/ULPA filter.

External structure in epoxy powder coated cold-rolled steel for excellent corrosion resistance to the attack by aggressive common chemicals.

Rear wall in epoxy coated steel, designed to conform to requirements and pass the €œcleanability test€� according to EN12469:2000.

Work surface in AISI 304L consisting of sections (or in one piece upon request) which are easily removable for carrying out routine cleaning and/or autoclaving sterilization procedures; closed or perforated on request.

Front window: electrically operated vertically sliding safety glass sash window.

Re-circulating and extractor fan: SafeFAST Classic are supplied with single centrifugal fan.

Servicing side glass with ports for service taps installation.

Filtration: H14 HEPA/ULPA filters with an efficiency better than 99,995 % MPPS (EN-1822).

Operation Condition: Air cleanliness in Class ISO 3 as per ISO:EN 14644-1.

The user-friendly practical keyboard and the rear-lit LCD will continuously display all required data keeping the user constantly informed of the cabinet conditions in operation, and in particular:

  • display of laminar airflow velocity and frontal air barrier velocity
  • display of inside and outside temperature
  • display of residual lifetime of HEPA/ULPA filters, UV Lamp and activated carbon filter (if fitted)
  • display of total number of hours of operation
  • display of saturation level of HEPA/ULPA filters.

Audio-visual alarms provided for:

  • out of range or incorrect laminar airflow velocity and frontal air barrier velocity
  • incorrect position of front sash-window
  • clogging of HEPA/ULPA filters
  • end of life-cycle of UV lamp and saturation of activated carbon filter (if fitted)
  • blockage in the exhaust duct ( if fitted )
  • fan-motor malfunction
  • power failure

Magnetic and removable UV sterilizing lamp (optional) that can be easily placed in each area of the back wall. It is completed with two switch-off countdown timers, one variable on a 0-3 hours scale (1 minute steps), the other set to 3 fixed hours.

Lighting: fluorescent tubes in built-in housing, placed outside the contaminated are

D.O.P.- DEHS inlet port for testing the HEPA/ULPA filters

Request More Info

Delivery

Return Policies

Request Specific Product Information

If the product info you require is not listed above, our dedicated UK team of lab product experts will be happy to provide what you are looking for. 

Delivery

Standard Delivery £15.00 +VAT. 

Delivery Schedule All in stock items will be dispatched within 2 working days.

Exemption The standard delivery fee does not apply to certain items. These may be subject to additional shipping charges, for example capital equipment items or dry ice shipments. Please contact our office for details.

Back Orders If your item is not in stock, we will back order it for you. Any in stock items on your order will be part-shipped on our standard delivery schedule at no additional charge. You will always be emailed with the option to cancel your order if you would rather not wait.

Return Policies

All goods supplied by the Company shall be examined and checked immediately upon receipt by the buyer. 

The company should be notified in writing within 48 hours of any damages, shortages or errors in the consignment. No claim whatsoever will be accepted by the Company in respect of any damage or shortage after this time. Where there is a total loss of the Goods in transit, the customer must notify the company within seven days of the invoice. If no such notice is given, the Goods shall be deemed to have been supplied in accordance with the order and to have been accepted by the Buyer. Goods that conform to the Buyer’s order may not be returned without the consent of the Seller. 

The Seller reserves the right to impose a handling charge of 20% of the net invoice value for returned Goods. The Seller reserves the right to refuse to accept any Goods returned, for whatever reason, if after inspection such Goods or their packaging prove unsatisfactory in any way. The Buyer is responsible for ensuring that any returns are free from biological and chemical hazard. The seller reserves the right to refuse to accept Goods which in its view present a hazard to its staff or which may infringe the Health & Safety at Work legislation.

Account Holder Benefits

Rewarding You and Your Lab For Shopping Local

As a UK independent lab supplier, we really appreciate you shopping local with us and supporting the UK science economy. To say thanks, all Appleton Woods account holders receive: 
  • Improved credit terms
  • Exclusive product offers and deals
  • Free entry into our monthly prize draws
  • Tickets to upcoming events
Screenshot_2024-09-05_at_13
AdobeStock_874167913_Preview
pexels-caleboquendo-7697342
Screenshot_2024-07-31_at_15